To ensure proper airflow and filter removal it is recom mended installation of the wall sleeve be a minimum of 36 from the ceiling.
Ptac wall sleeve installation.
The sleeve will fit flush in the wall extending outside the structure.
Install the sleeve and secure with mounting fasteners.
All wall and window wall installations must provide for proper drainage.
It s a good idea to frame the ptac unit with substantial secure wood studs.
Summary the above is the basic steps to install a through the wall air conditioner sometimes call a window wall slide out air conditioner.
Unit has a slight rearward slope within wall sleeve for proper drainage use tapered foam blocks.
Keys to proper installation.
Sleeve must be tight against the bottom shim and fully bedded into sealant.
Install a backer rod if necessary to maintain a consistent gap between the louver frame flange and ptac sleeve across the top and down both sides.
Power it on and test it.
Wall sleeve installation 920 087 04 8 05 wall sleeve installation instructions pdxws note.
The air conditioner will slide into the sleeve but is not flush with the wall.
In applications where the drain holes on the ptac wall sleeve are not exposed beyond the wall an internal drain system is recommended.
Supporting and sealing sleeve to their frames.
Every scenario will be different with wall type and power always changing.
Place the unit into the sleeve and screw it in place.
It is the insta oohu vuhvsrqvlelolw to ensure there is adequate drainage for the ptac.
Cooper and hunter 9 000 btu ptac packaged terminal air conditioner with heat pump pthp unit full set including steel installation sleeve and grille 5 0 out of 5 stars 1 1 055 00 1 055.
If the sleeve projects more than 8 into the room a sub base or other means of support must be used.
When installing a ptac unit an anchored stable installation will improve performance and increase longevity.
Wall sleeve is secure and properly sealed to the wall.
Caulk along the outside sleeve edges to prevent leaks.
There is a portion of the air conditioner which extends a few inches back into the room.
Inches mm inches mm inches mm wall sleeve only 3 75 0 0 0 0 subbase kit 3 75 3 1 4 85 2 3 4 70.
Figure 4 minimum interior and exterior note.
Apply sealant to completely fill this pocket.
Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve chassis and accessories.
The wall sleeve be installed a minimum of 36 from the ceiling.